» Chvac Basics video series is now available for viewing. » Fire Basics video is now available for viewing. ✿ire Standpipe video is now available for viewing. ✿ire Pump video is now available for viewing. »Rhvac Online upload and download video is now available for viewing. »New Video for converting an Rhvac Room Data window project to Drawing Board. »New Videos for creating custom materials in Rhvac and Rhvac Online »New Update Manager is available for downloading. » Come see us at the 2023 AHR Expo in Atlanta. S-Pipe - Design and analyze domestic supply water piping systems. Light - Design indoor lighting with zonal cavity calculations.įire - Design and analyze fire sprinkler systems. HVAC Tools - Perform 13 common HVAC design tasks.Įlectrical Tools - Perform common electrical calculation and data look-up tasks. Rhvac - Calculate Manual J heating and cooling loads for residential buildings, both block load and room-by-room.Ĭhvac - Calculate ASHRAE based heating and cooling loads for commercial buildings. Our HVAC software sets the standard for excellence and ease-of-use in the industry. Over 30 programs are offered for such applications as HVAC load calculations, building energy analysis, HVAC duct and pipe sizing, plumbing & lighting design, fault current calculations, voltage drops, fuse and breaker coordination, and much more. The experimental study indicated that convection and radiation separating method on wall could calculate the radiant cooling load of floor.National Comfort Institute recommends Elite Software for High Performance ContractorsĮngineering Design Software for Engineers, Architects and ContractorsĮlite Software is the world's premier software developer for HVAC, electrical, plumbing, and fire protection design software. Its mean absolute error is 1.2% and 1.7% respectively. The results for the 5 experimental conditions show that the radiant cooling load of floor peak error is less than 2.3% comparing with the value which is calculated by radiant time series method, and average error is not more than 3.2%. Based on experimental data of total heat gain and total cooling loads collected within 24-hours, radiant heat gain of floor can be calculated through convection and radiation separating method, using PRF/RTF Generator software to calculate the radiant time factor of floor the radiant cooling load of floor is calculated and compared with the measured values. A calculation method about the radiant cooling load of floor which is based on radiant time series (RTS) method is presented: With the use of radiant time factors, radiant cooling load can be easily calculated from the radiant heat gain.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
January 2023
Categories |